Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 249: 123659, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35728452

RESUMO

Quartz crystal microbalance (QCM)-based biosensors are highly attractive as rapid diagnostic devices for detecting infectious diseases. However, the fabrication of QCM-based biosensors often involves tedious processes due to the poor stability of the biological recognition elements. In this work, the simple self-polymerisation of dopamine was used to functionalise the QCM crystal surface with a molecularly imprinted polydopamine (MIPDA) sensing film for detecting the hepatitis B core antigen (HBcAg), a serological biomarker of hepatitis B. Recognition cavities that complemented the size and shape of HBcAg were observed on the QCM crystal surface after functionalisation with the MIPDA film. The MIPDA-QCM biosensor showed a selective affinity for HBcAg, recording frequency responses up to 7.8 folds larger towards HBcAg compared to human serum albumin at the same analyte concentrations. The biosensor response was enhanced by using the optimal concentrations of 10 mg mL-1 of dopamine and 1 mg mL-1 of template for MIPDA film formation, resulting in a low detection limit (0.88 µg mL-1) that enables the detection of clinically relevant titres of HBcAg. The detection process could be completed within 10 min after sample loading without additional steps for signal amplification, highlighting the practical advantages of the MIPDA-QCM biosensor for point-of-care detection of hepatitis B.


Assuntos
Técnicas Biossensoriais , Hepatite B , Impressão Molecular , Técnicas Biossensoriais/métodos , Dopamina , Hepatite B/diagnóstico , Antígenos da Hepatite B , Antígenos do Núcleo do Vírus da Hepatite B , Humanos , Indóis , Impressão Molecular/métodos , Polímeros , Quartzo , Técnicas de Microbalança de Cristal de Quartzo
2.
Biosens Bioelectron ; 168: 112513, 2020 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-32889395

RESUMO

Infectious diseases are the ever-present threats to public health and the global economy. Accurate and timely diagnosis is crucial to impede the progression of a disease and break the chain of transmission. Conventional diagnostic techniques are typically time-consuming and costly, making them inefficient for early diagnosis of infections and inconvenient for use at the point of care. Developments of sensitive, rapid, and affordable diagnostic methods are necessary to improve the clinical management of infectious diseases. Quartz crystal microbalance (QCM) systems have emerged as a robust biosensing platform due to their label-free mechanism, which allows the detection and quantification of a wide range of biomolecules. The high sensitivity and short detection time offered by QCM-based biosensors are attractive for the early detection of infections and the routine monitoring of disease progression. Herein, the strategies employed in QCM-based biosensors for the detection of infectious diseases are extensively reviewed, with a focus on prevalent diseases for which improved diagnostic techniques are in high demand. The challenges to the clinical application of QCM-based biosensors are highlighted, along with an outline of the future scope of research in QCM-based diagnostics.


Assuntos
Técnicas Biossensoriais , Doenças Transmissíveis , Doenças Transmissíveis/diagnóstico , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas de Microbalança de Cristal de Quartzo
3.
Nanoscale ; 10(31): 15103-15115, 2018 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-30059122

RESUMO

The early detection and accurate characterization of life-threatening diseases such as cardiovascular disease and cancer are critical to the design of treatment. Knowing whether or not a thrombus in a blood vessel is new (fresh) or old (constituted) is very important for physicians to decide a treatment protocol. We have designed smart MRI nano-sensors that can detect, sense and report the stage or progression of cardiovascular diseases such as thrombosis. The nanosensors were functionalized with fibrin-binding peptide to specifically target thrombus and were also labelled with fluorescent dye to enable optical imaging. We have demonstrated that our nanosensors were able to switch between the T1 and T2 signal depending on thrombus age or the presence or absence of thrombin at the thrombus site. The developed nanosensors appeared to be non-toxic when tested with Chinese Hamster Ovarian cells within the tested concentrations. The working principle demonstrated in this study can be applied to many other diseases such as cancer.


Assuntos
Imageamento por Ressonância Magnética , Nanopartículas Metálicas , Trombina/análise , Trombose/diagnóstico por imagem , Animais , Células CHO , Cricetulus , Compostos Férricos , Humanos , Peptídeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...